<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2602-8492</journal-id>
<journal-title><![CDATA[Revista Técnica energía]]></journal-title>
<abbrev-journal-title><![CDATA[Revista Técnica energía]]></abbrev-journal-title>
<issn>2602-8492</issn>
<publisher>
<publisher-name><![CDATA[Operador Nacional de Electricidad CENACE]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2602-84922019000200008</article-id>
<article-id pub-id-type="doi">10.37116/revistaenergia.v16.n1.2019.330</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Diseño e Implementación de una (PMU) de baja potencia para Sistemas Trifásicos de Distribución bajo la norma IEEE C37.118.1]]></article-title>
<article-title xml:lang="en"><![CDATA[Design and Construction of a Low-Cost Phasor Measurement Unit (PMU) for Three- Phase Distribution Power Systems according to the norm IEEE C37.118.1]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Guamán]]></surname>
<given-names><![CDATA[A. R.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pozo]]></surname>
<given-names><![CDATA[P. M.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pozo]]></surname>
<given-names><![CDATA[I. A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pozo]]></surname>
<given-names><![CDATA[N. A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Escuela Politécnica Nacional Departamento de Automatización y Control Industrial ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Escuela Politécnica Nacional Departamento de Automatización y Control Industrial ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Escuela Politécnica Nacional Departamento de Automatización y Control Industrial ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Escuela Politécnica Nacional Departamento de Automatización y Control Industrial ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2019</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2019</year>
</pub-date>
<volume>16</volume>
<numero>1</numero>
<fpage>8</fpage>
<lpage>16</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_arttext&amp;pid=S2602-84922019000200008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_abstract&amp;pid=S2602-84922019000200008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_pdf&amp;pid=S2602-84922019000200008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen: Las Unidades de Medición Sincrofasorial (PMU) son ampliamente usadas en la supervisión en tiempo real de los sistemas eléctricos de potencia. En este trabajo se presenta el diseño e implementación de una PMU prototipo de bajo costo que permite estimar fasores, frecuencia, tasa de cambio de frecuencia y componentes simétricas con la etiqueta de tiempo correspondiente a cada valor estimado en una red trifásica de baja potencia utilizando el estándar IEEE C37.118.1. Cada uno de estos parámetros se sincronizan usando como referencia de tiempo las señales provenientes de un Sistema de Posicionamiento Global (GPS). El sistema utiliza como base una plataforma de desarrollo controlada por un Procesador Digital de Señales (DSP) y la estimación de los sincrofasores se realiza usando la Transformada Discreta de Fourier (DFT). Inicialmente se presenta un método de estimación fasorial, luego se describe el hardware y software implementado, después se presentan los resultados obtenidos de las mediciones efectuadas para verificar el correcto funcionamiento del equipo. Finalmente se efectúan pruebas convencionales para validar las mediciones que realiza la PMU para el uso clase P y pruebas que permiten verificar los parámetros de operación de acuerdo con la norma IEEE C37.118.1.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: Phasor Measurement Units (PMU) are widely used in the real-time monitoring of electrical power systems. This work presents the design and construction of a low-cost prototype of PMU. This system allows to estimate phasors, frequency, rate of change of frequency and symmetric components with the time label corresponding to each value estimated in a three-phase network of low power using the IEEE standard C37.118.1. All these parameters are synchronized using the signals from a Global Positioning System GPS asa time reference. The system uses as a base a development platform controlled by a Digital Signal Processor (DSP) and the estimation of the synchrophasors is done using the Discrete Fourier Transform (DFT). Initially, a phasor estimation method is presented, after the implemented hardware and software is described, then the results obtained from the measurements are presented in order to verify the correct functioning of the equipment. Finally, operation tests are performed to validate the prototype according to the IEEE C37.118.1 standard.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Estimación Fasorial]]></kwd>
<kwd lng="es"><![CDATA[Procesador Digital de Señales]]></kwd>
<kwd lng="es"><![CDATA[PMU]]></kwd>
<kwd lng="es"><![CDATA[Transformada Discreta de Fourier]]></kwd>
<kwd lng="es"><![CDATA[Unidad de M edición Sincrofasorial]]></kwd>
<kwd lng="en"><![CDATA[Digital Signal Processor]]></kwd>
<kwd lng="en"><![CDATA[Discrete Fourier Transform]]></kwd>
<kwd lng="en"><![CDATA[Fasorial Estimation]]></kwd>
<kwd lng="en"><![CDATA[Phasor Measurement Unit]]></kwd>
<kwd lng="en"><![CDATA[PMU.]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guamán]]></surname>
<given-names><![CDATA[A. R.]]></given-names>
</name>
</person-group>
<source><![CDATA[Diseño e implementación de un medidor sincrofasorial de baja potencia bajo la norma IEEE C37.118.1]]></source>
<year>2018</year>
<publisher-loc><![CDATA[Quito, Ecuador ]]></publisher-loc>
<publisher-name><![CDATA[DACI, Escuela Politécnica Nacional]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="">
<collab>GPS</collab>
<source><![CDATA[The Global Positioning System]]></source>
<year>2017</year>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="book">
<source><![CDATA[The Data Conversion Handbook]]></source>
<year>2005</year>
<edition>1st ed</edition>
<publisher-loc><![CDATA[Burlington ]]></publisher-loc>
<publisher-name><![CDATA[Oxford]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Faúndez]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Módems," en Sistemas de Comunicaciones]]></source>
<year>2001</year>
<page-range>208-42</page-range><publisher-loc><![CDATA[Barcelona, España: Marcombo ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Correia]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Guía Práctica del GPS]]></source>
<year>2002</year>
<publisher-loc><![CDATA[Barcelona: Marcombo ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="">
<collab>FLUKE</collab>
<source><![CDATA[Sistema de calibración de unidad de medición fasoreal 6135A / PMUCAL]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<source><![CDATA[Diseño e implementación de un medidor fasorial síncrono normalizado]]></source>
<year>2009</year>
<publisher-loc><![CDATA[México D.F., ]]></publisher-loc>
<publisher-name><![CDATA[Instituto Politécnico Nacional]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Synchronized Phasor Measurement and Their Aplications]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Phadke]]></surname>
<given-names><![CDATA[A. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Thorp]]></surname>
<given-names><![CDATA[J. S.]]></given-names>
</name>
</person-group>
<source><![CDATA[New York: Springer]]></source>
<year>2008</year>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Introduction To Symmetrical Components]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kirtley]]></surname>
<given-names><![CDATA[J.L.]]></given-names>
</name>
</person-group>
<source><![CDATA[MIT]]></source>
<year>2001</year>
<publisher-loc><![CDATA[Dept. Electrical Engineering and Computer Science ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="">
<collab>Linx</collab>
<source><![CDATA[Anntenna Factor by Linx]]></source>
<year>2014</year>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="">
<source><![CDATA[LAUNCHXL-F28379D Overview]]></source>
<year></year>
<publisher-loc><![CDATA[Texas Instruments ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="">
<collab>Vacuumschmelze</collab>
<source><![CDATA[15 A Current Sensor for 5V- Supply Voltage]]></source>
<year>2014</year>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="">
<collab>FLUKE</collab>
<source><![CDATA[Fluke 80 Series V Digital Multimeters: The Industrial Standard]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="">
<collab>IEEE Standard C37.119.1</collab>
<source><![CDATA[IEEE Standard for Synchrophasor Measurements for Power Systems]]></source>
<year>2011</year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
