<article-title xml:lang="es"><![CDATA[Control de Velocidad Directo de un Aerogenerador de 9 MW]]></article-title>
<article-title xml:lang="en"><![CDATA[Direct Speed Control of a 9 MW DFIG Wind Turbine]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pozo]]></surname>
<given-names><![CDATA[Adrián]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[Eduardo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ayala]]></surname>
<given-names><![CDATA[Edy]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Politécnica Salesiana  ]]></institution>
<addr-line><![CDATA[Cuenca ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad Politécnica Salesiana  ]]></institution>
<addr-line><![CDATA[Cuenca ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad Politécnica Salesiana  ]]></institution>
<addr-line><![CDATA[Cuenca ]]></addr-line>
<country>Ecuador</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2021</year>
</pub-date>
<volume>18</volume>
<numero>1</numero>
<fpage>11</fpage>
<lpage>18</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_arttext&amp;pid=S2602-84922021000200011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_abstract&amp;pid=S2602-84922021000200011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_pdf&amp;pid=S2602-84922021000200011&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen: El siguiente artículo muestra la descripción, implementación y validación de una estrategia de control para el seguimiento del punto máximo de potencia (MPPT) de un aerogenerador de inducción doblemente alimentado (DFIG). Esta estrategia se desarrolla conforme la teoría del control de velocidad indirecto (ISC) y la teoría de observadores de estado tomando como variable de ingreso la velocidad angular de la hélice. Este mecanismo de control permite realizar el seguimiento del MPPT, llevando así el Coeficiente de Potencia (Cp) a su valor optimo durante la operación del aerogenerador. El controlador, entre sus características principales, está configurado para trabajar con la incorporación de estímulos aleatorios de viento lo cual permite anticipar su respuesta a una perturbación. Para los experimentos se seleccionó un aerogenerador de 1,5 MW, este modelo se implementó por medio de Matlab y el software Fatiga, Aerodinámica, Estructuras y Turbulencia FAST.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: In the present work, a control strategy for Maximum Power Point Tracking (MPPT) of a wind turbine based on a Doubly Fed Induction Generator (DFIG) is described. This strategy is developed according to the theory of Di-rect Speed Control (DSC) which includes a state observer. This strategy con-siders the Low Shaft Speed (LSS) as an input and the Iqr reference current as the output. This control mechanism allows monitoring the MPPT; thus, changing the Power coefficient (Cp) to its optimal value during the operation of the wind turbine. The controller, among its main features, is configured to work with the incorporation of different wind inputs; fact that permits evaluating the system response to disturbances and variations. For simulations tests, a 1,5 MW wind turbine has been modeled in Matlab and Fatigue, Aero-dynamics, and Structures and Turbulence FAST software. The strategy has been compared to a PI MPPT controller and has demonstrated improvements in terms of speed and output power extraction.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Coeficiente de potencia]]></kwd>
<kwd lng="es"><![CDATA[MPPT]]></kwd>
<kwd lng="es"><![CDATA[control de velocidad directo]]></kwd>
<kwd lng="es"><![CDATA[DFIG]]></kwd>
<kwd lng="es"><![CDATA[aerogenerador]]></kwd>
<kwd lng="es"><![CDATA[ruido blanco]]></kwd>
<kwd lng="en"><![CDATA[Power coefficient]]></kwd>
<kwd lng="en"><![CDATA[MPPT]]></kwd>
<kwd lng="en"><![CDATA[direct speed control]]></kwd>
<kwd lng="en"><![CDATA[DFIG]]></kwd>
<kwd lng="en"><![CDATA[wind turbine]]></kwd>
<kwd lng="en"><![CDATA[white noise.]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Neural network based control of Doubly Fed Induction Generator in wind power generation]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barbade]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Kasliwal]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Advancements in Research &amp; Technology]]></source>
<year>2012</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1-5</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lal Senanayaka]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Robbersmyr]]></surname>
<given-names><![CDATA[KG]]></given-names>
</name>
<name>
<surname><![CDATA[Karimi]]></surname>
<given-names><![CDATA[HR]]></given-names>
</name>
</person-group>
<source><![CDATA[Direct Torque Control of a Small Wind Turbine with a Sliding-Mode Speed Controller]]></source>
<year>2016</year>
<conf-name><![CDATA[ Journal of Physics: Conference Series 753 (2016) 052031]]></conf-name>
<conf-date>2016</conf-date>
<conf-loc> </conf-loc>
<page-range>1-11</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Doubly Fed Induction Generators Systems for Wind Turbines]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muller]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Deicke]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<collab>DRW</collab>
<source><![CDATA[IEEE Industry Applications]]></source>
<year>2000</year>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>26-33</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Indirect Speed Control Strategy for Monitoring the Maximum Power Point of a DFIG Wind Power System]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ayala]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Pozo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Simani]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Technical Magazine "Energía"]]></source>
<year>2020</year>
<page-range>92-101</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ayala]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Simani]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Perturb and observe maximum power point tracking algorithm for permanent magnet synchronous generator wind turbine systems.]]></source>
<year>2019</year>
<conf-name><![CDATA[ Proceedings of the 15th European Workshop on Advanced Control and Diagnostics]]></conf-name>
<conf-date>2019</conf-date>
<conf-loc> </conf-loc>
<page-range>1-11</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abad]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Lopez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Miguel]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Marroyo]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Iwanski]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[Doubly Fed Induction Machine]]></source>
<year>2011</year>
<publisher-name><![CDATA[WILEY]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Modeling and Control of a Doubly Fed Induction Generator Based Wind Turbine System]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hallak]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Hasni]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Menaa]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[3rd CISTEM'18]]></source>
<year>2018</year>
<page-range>1-15</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Performance Improvements of Switching Control for Wind Turbines]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Palejiya]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Sustainable Energy]]></source>
<year>2016</year>
<volume>7</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>526-34</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Gain-Scheduled to Optimal Control of Variable-Speed-Variable-Pitch Wind Turbines]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jafarnejadsani]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Pieper]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Control Systems Technology]]></source>
<year>2015</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>372-9</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Optimal Real-Time Control of Wind Turbine During Partial Load Operation]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Yan]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Shaltout]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Control Systems Technology]]></source>
<year>2015</year>
<volume>23</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>2216-26</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="book">
<collab>National Renewable Energy Laboratory (NREL)</collab>
<source><![CDATA[Fatigue Aerodynamics Structures and Turbulence]]></source>
<year>2020</year>
<publisher-name><![CDATA[NREL]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="">
<collab>Matlab</collab>
<source><![CDATA[The MathWorks Inc]]></source>
<year>2020</year>
<publisher-loc><![CDATA[Massachusetts ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Adaptive neuro-fuzzy maximal power extraction of wind turbine with continuously variable transmission]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Petkovi&#263;]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[&#262;ojba&#353;i&#263;]]></surname>
<given-names><![CDATA[&#381;.]]></given-names>
</name>
<name>
<surname><![CDATA[Nikoli&#263;]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Shamshirband]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Kia]]></surname>
<given-names><![CDATA[MLM]]></given-names>
</name>
<name>
<surname><![CDATA[Anuar]]></surname>
<given-names><![CDATA[NB]]></given-names>
</name>
<name>
<surname><![CDATA[Wahab]]></surname>
<given-names><![CDATA[AWA]]></given-names>
</name>
</person-group>
<source><![CDATA[Energy]]></source>
<year>2014</year>
<volume>64</volume>
<page-range>868-74</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Uluyol]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Parthasarathy]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Foslien]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<source><![CDATA[Power Curve Analytic for Wind Turbine Performance Monitoring and Prognostics]]></source>
<year>2011</year>
<conf-name><![CDATA[ Annual Conference of the Prognostics and Health Management Society]]></conf-name>
<conf-date>2011</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Robust Control of Doubly Fed Induction Generator for Wind Turbine Under Sub-synchronous Operation Mode]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bedoud]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Ali-rachedi]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Bahi]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Lakel]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Grid]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Energy Procedia]]></source>
<year>2015</year>
<volume>74</volume>
<page-range>886-99</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Maximum Power Point Tracking in Grid Connected Wind Plant by Using Intelligent Controller and Switched Reluctance Generator]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rahmanian]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Akbari]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Sheisi]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Sustainable Energy]]></source>
<year>2017</year>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1313-20</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Standalone Operation of Wind Standalone Operation of Wind Capability]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mendis]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Muttaqi]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Sayeef]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Perera]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Energy Conversion]]></source>
<year>2012</year>
<volume>27</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>822-34</page-range></nlm-citation>
</ref>