<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2602-8492</journal-id>
<journal-title><![CDATA[Revista Técnica energía]]></journal-title>
<abbrev-journal-title><![CDATA[Revista Técnica energía]]></abbrev-journal-title>
<issn>2602-8492</issn>
<publisher>
<publisher-name><![CDATA[Operador Nacional de Electricidad CENACE]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2602-84922020000100009</article-id>
<article-id pub-id-type="doi">10.37116/revistaenergia.v16.n2.2020.348</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Estimación de los Parámetros Eléctricos de una Línea de Transmisión Trifásica a Escala de Laboratorio a Partir de Mediciones de Transitorios de Voltaje]]></article-title>
<article-title xml:lang="en"><![CDATA[Estimation of the Electrical Parameters of a Laboratory-Scale Three-Phase Transmission Line from Transient Voltage Measurements]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gualotuña]]></surname>
<given-names><![CDATA[René]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[Juan]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lucio]]></surname>
<given-names><![CDATA[Miguel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Granda]]></surname>
<given-names><![CDATA[Nelson]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Quilumba]]></surname>
<given-names><![CDATA[Franklin]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Escuela Politécnica Nacional  ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Escuela Politécnica Nacional  ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Escuela Politécnica Nacional  ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Escuela Politécnica Nacional  ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af5">
<institution><![CDATA[,Escuela Politécnica Nacional  ]]></institution>
<addr-line><![CDATA[Quito ]]></addr-line>
<country>Ecuador</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2020</year>
</pub-date>
<volume>16</volume>
<numero>2</numero>
<fpage>9</fpage>
<lpage>18</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_arttext&amp;pid=S2602-84922020000100009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_abstract&amp;pid=S2602-84922020000100009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.senescyt.gob.ec/scielo.php?script=sci_pdf&amp;pid=S2602-84922020000100009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen: En este artículo se presenta la estimación de los parámetros eléctricos de una línea de transmisión trifásica a partir de mediciones de transitorios de voltaje en un modelo de laboratorio a escala utilizando métodos de optimización no lineal. El objetivo del estudio busca obtener los parámetros de forma más precisa y rápida en comparación con los métodos convencionales. Las pruebas convencionales de circuito abierto y corto circuito se realizaron en un modelo a escala en el Laboratorio de Máquinas Eléctricas de la Escuela Politécnica Nacional y se utilizaron para obtener los parámetros eléctricos iniciales del modelo. Posteriormente, se simula un evento de voltaje transitorio mediante la energización de la línea utilizando un interruptor que proporciona una señal de voltaje experimental. La señal es capturada por un instrumento de medición para su posterior análisis. Con la ayuda de MATLAB-Simulink, la simulación de la línea de transmisión se realiza con el respectivo transitorio de voltaje obtenido al energizar la línea, con un voltaje nominal y sin carga. En la simulación se utilizan los parámetros obtenidos de manera convencional, el modelo de parámetros distribuidos de la línea de transmisión y el evento de voltaje transitorio. Finalmente, se utiliza la herramienta de optimización Parameter Estimation de MATLAB-Simulink para sintonizar la señal de la respuesta experimental y la simulación.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: This article presents the estimation of the electrical parameters of a three-phase transmission line from measurements of transient voltages in a laboratory-scale model using non-linear optimization methods. The aim of the study is to be able to determine the parameters more accurately and faster compared to conventional methods. The conventional tests open circuit and short circuit were conducted on a scale model in the Laboratory of Electrical Machines at the National Polytechnic School. The parameters derived from these tests constitute the initial electrical parameters of the model. Subsequently, a transient voltage event is simulated by energizing the line by means of a switch that provides an experimental voltage signal. The signal is captured by a recording instrument for subsequent analysis. With the help of MATLAB-Simulink, the simulation of the transmission line is performed with the respective voltage transient obtained by energizing the line, with a nominal voltage and no load. In the simulation the parameters obtained in the conventional tests, the distributed parameter model of the transmission line and the transient voltage event are used. Finally, the MATLAB-Simulink Parameter Estimation optimization tool is used to tune the transmission line parameters, so the signal of the simulation resembles as close as possible to the experimental response.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Línea de transmisión de alto voltaje]]></kwd>
<kwd lng="es"><![CDATA[sintonización de parámetros]]></kwd>
<kwd lng="es"><![CDATA[sobrevoltajes transitorios]]></kwd>
<kwd lng="es"><![CDATA[optimización no lineal]]></kwd>
<kwd lng="en"><![CDATA[High voltage transmission line]]></kwd>
<kwd lng="en"><![CDATA[parameter estimation]]></kwd>
<kwd lng="en"><![CDATA[transient voltage]]></kwd>
<kwd lng="en"><![CDATA[nonlinear optimization]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Estimation of transmission line parameters from measurements]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Indulkar]]></surname>
<given-names><![CDATA[C. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ramalingam]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<source><![CDATA[International Journal of Electrical Power &amp; Energy Systems]]></source>
<year>2008</year>
<volume>30</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>337-42</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Estimation of transmission line parameters using multiple methods]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[E. C. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Kurokawa]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[IET Generation Transmission &amp; Distribution]]></source>
<year>2015</year>
<volume>9</volume>
<numero>16</numero>
<issue>16</issue>
<page-range>2617-24</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Modelos de línea de transmisión para transitorios electromagnéticos en sistemas de potencia]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[L. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Delgado]]></surname>
<given-names><![CDATA[G. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Aranda]]></surname>
<given-names><![CDATA[F. Castro]]></given-names>
</name>
</person-group>
<source><![CDATA[Revista Energía y Computación]]></source>
<year>2008</year>
<volume>16</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>21-32</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Series expansions for line series impedances considering different specific resistances, magnetic permeabilities, and dielectric permittivities of conductors, air, and ground]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hofmann]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Power Delivery]]></source>
<year>2003</year>
<volume>18</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>564-70</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zivanovic]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<source><![CDATA[Estimation of transmission line parameters using fault records]]></source>
<year>2006</year>
<conf-name><![CDATA[ Proceedings of the AUPEC, 06]]></conf-name>
<conf-date>2006</conf-date>
<conf-loc>Melbourne, Australia </conf-loc>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Simplified procedure to estimate the resistance parameters of transmission lines]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kurokawa]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Asti]]></surname>
<given-names><![CDATA[G. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[E. C. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Pissolato]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrical Engineering]]></source>
<year>2013</year>
<volume>95</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>221-7</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schulze]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Schegner]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Stachel]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Parameter identification of unsymmetrical transmission lines using accurately re-synchronised fault records]]></source>
<year>2009</year>
<conf-name><![CDATA[ 2009 IEEE Power Tech]]></conf-name>
<conf-date>2009</conf-date>
<conf-loc>Bucharest </conf-loc>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Accurate Modelling of Frequency-Dependent Transmission Lines in Electromagnetic Transient Simulations]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Marti]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Transactions on Power Apparatus and Systemps]]></source>
<year>1982</year>
<volume>PAS-101</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>147-57</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grainger]]></surname>
<given-names><![CDATA[J. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Stevenson]]></surname>
<given-names><![CDATA[W. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[G.W.]]></given-names>
</name>
</person-group>
<source><![CDATA[Power System Analysis]]></source>
<year>2003</year>
<publisher-name><![CDATA[McGraw-Hill Education]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kothari]]></surname>
<given-names><![CDATA[D. P.]]></given-names>
</name>
<name>
<surname><![CDATA[Nagrath]]></surname>
<given-names><![CDATA[I. J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Modern Power System Analysis.]]></source>
<year>2011</year>
<publisher-name><![CDATA[McGraw-Hill Education]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Trujillo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Análisis de modelos de cálculo de parámetros de líneas de transmisión]]></source>
<year>2013</year>
<publisher-loc><![CDATA[Quito, Ecuador ]]></publisher-loc>
<publisher-name><![CDATA[Escuela Politécnica Nacional]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernandes]]></surname>
<given-names><![CDATA[A. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Neves]]></surname>
<given-names><![CDATA[W. L. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[E. G. da]]></given-names>
</name>
<name>
<surname><![CDATA[Cavalcanti]]></surname>
<given-names><![CDATA[M. N.]]></given-names>
</name>
</person-group>
<source><![CDATA[The Effect of the Shunt Conductance on Transmission Line Models]]></source>
<year>2001</year>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Estimación de los Parámetros Eléctricos de un Generador Sincrónico basada en Mediciones de Laboratorio usando Métodos de Optimización No Lineal]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chiguano]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Quilumba]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Gallardo]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Revista Técnica Energía]]></source>
<year>2018</year>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Digital Computer Solution of Electromagnetic Transients in Single-and Multiphase Networks]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dommel]]></surname>
<given-names><![CDATA[H. W.]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans. Power Appar. Syst.]]></source>
<year>1969</year>
<volume>PAS-88</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>388-99</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodas]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudio de una línea de transmisión mediante un modelo]]></source>
<year>1970</year>
<publisher-loc><![CDATA[Quito, Ecuador ]]></publisher-loc>
<publisher-name><![CDATA[Escuela Politécnica Nacional]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Horak]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Zero sequence impedance of overhead transmission lines]]></source>
<year>2006</year>
<conf-name><![CDATA[ 59thAnnual Conference for Protective Relay Engineers]]></conf-name>
<conf-date>2006</conf-date>
<conf-loc>College Station, Texas, Estados Unidos de América </conf-loc>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chiguano]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<source><![CDATA[Estimación de parámetros eléctricos de la máquina sincrónica utilizando MATLAB-Simulink]]></source>
<year>2018</year>
<publisher-loc><![CDATA[Quito, Ecuador ]]></publisher-loc>
<publisher-name><![CDATA[Escuela Politécnica Nacional]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
