SciELO - Scientific Electronic Library Online

 
 issue24Monitoring network to automate the cooling system of a data center author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Ingenius. Revista de Ciencia y Tecnología

On-line version ISSN 1390-860XPrint version ISSN 1390-650X

Abstract

QUITIAQUEZ, William et al. Análisis numérico de un sistema de calentamiento de agua utilizando un colector solar de placa plana. Ingenius [online]. 2020, n.24, pp.97-106. ISSN 1390-860X.  https://doi.org/10.17163/ings.n24.2020.10.

The aim of the present investigation was to perform a flat plate solar collector numerical analysis by CFD, in addition to a comparison with experimental results. The working fluid reached a maximum outlet temperature of 20.16 °C at 12:00, the value of solar radiation was determined for the geographical coordinates latitude -0.2252 and longitude -77.84, similarly, at this time it was possible to obtain a collector surface temperature of 27.12 °C, as a peak value. The heat transfer device lowest performance was determined at 10:00 with an outlet water temperature value and maximum temperature at the collector surface of 18.65 and 20.48 °C, respectively. The experimental results showed a maximum temperature of 20.93 °C and a minimum temperature of 19.4 °C, resulting in a 4.01 % error between the computational simulation and the experimental data.

Keywords : colector; energía solar; temperatura; simulación CFD.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )