SciELO - Scientific Electronic Library Online

 
vol.8 número2Modelado de base fenomenológica del secador ATM-52 empleado en el proceso de producción de pasta cerámica índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Maskay

versão impressa ISSN 1390-6712

Resumo

VALLEJO, Henry; PAUCAR, Jorge  e  MARTINEZ, Oswaldo. Artificial vision through the correlation coefficient for retinoscopy examinations. Maskay [online]. 2018, vol.8, n.2, pp.75-80. ISSN 1390-6712.  https://doi.org/10.24133/maskay.v8i2.1059.

An automated system was designed and implemented to perform retinoscopy examinations using artificial vision with the correlation coefficient for the processing of retinal images. The technique of observation and experimentation was used to identify the necessary conditions involved in performing the retinoscopy examination. A mechanical, electronic and artificial vision system design was established for the selection and installation of the necessary components for the automation. For the operation of the automated system an algorithm of processing and comparison of images programmed in the LabVIEW software was developed; through a connection to the serial port, data is sent from the computer to the Arduino Uno development board, which controls actuators that are servomotors that direct the position of the lenses and effect the movement of the light beam of the retinoscope. For the automatic change of lenses, a suitable mechanical system was implemented in order to obtain a fixed image of the retina; a human machine interface (HMI) was created, which allows the operator to view the examination process in real time. With the implementation of the system the average time of the image comparison was determined, with the result that: eyes without ametropia were compared in 162,28 ms, myopia in 166,02 ms, with farsightedness in 170,7 ms and with astigmatism in 174,75 ms, reducing the time taken to perform the retinoscopy examination of 250 to 150 seconds equivalent to 40%. It was concluded that the time of comparison of the images increase in 2.44% while the sea was the refractive damage.

Palavras-chave : retinoscope; processing of retinal images; artificial vision; retinal images; retinoscopy examinations.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )